  • Information

     

    Model 6A0510 6A0520 6A0530 6A110 6A120 6A130
    Port size [Note 1] In=Out=Exh=M5

    In=Out=Exh=M5(or=1/8")

    Orifice size
    (Cv) [Note 4]
    M5:3.4mm2(0.2) 6A0530CM5:
    2.2mm2(0.13)
    06:8.9mm2(0.52) 6A130C06:
    8.0mm2(0.47)
    Weight (g) 20 25 30 50 60 65
    Model 6A210 6A220 6A230 6A310 6A320 6A330
    Port size [Note 1] In=Out=1/8"(or=1/4")  Exh=1/8" In=Out=3/8"  Exh=1/4"
    Orifice size
    (Cv) [Note 4]
    08:15.4mm2(0.91) 6A230C08:
    14.2mm2(0.84)
    10:38.4mm2(2.26) 6A330C10:
    30.5mm2(1.8)
    Weight (g) 120 135 145 250 290 320
    Fluid Air (to be filtered by 40μm filter element)
    Acting External air control
    Operating
    pressure
    5/3 way 0.2~0.8Mpa(29~114psi)

    5/2 way

    0.15~0.8Mpa(21~114psi)
    Proof pressure 1.2MPa(175psi)
    Temperature -20~70℃
    Material of body Aluminum alloy
    Lubrication [Note 2] Not required
    Max.frequency [Note 3] 5 cycle/sec 3 cycle/sec 5 cycle/sec 3 cycle/sec

    [Note 1] PT , NPT  , G thread are available.

    [Note 2] Once lubricated air is used, continue with same medium to optimise valve life span.

                  Lubricants like ISO VG32 or equivalent are recommended.

    [Note 3] The maximum actuation frequency is in the no-load state.

    [Note 4] Equivalent orifice S and Cv are all calculated from the flow rate data.

     