Model 6HV0510 6HV0520 6HV0530 6HV110 6HV120 6HV130 Port size [Note 1] In=Out=M5 In=Out=M5(or=1/8") Orifice size
(Cv) [Note 4]M5:3.4mm2(0.2) 6HV0530CM5:
2.2mm2(0.13)06:8.9mm2(0.52) 6HV130C06:
8.0mm2(0.47)Max.frequency [Note 3] 5 cycle/sec 3 cycle/sec 5 cycle/sec 3 cycle/sec Fluid Air(to be filtered by 40μm filter element) Acting Pilot Operating
pressure6HV0530/6HV130 0.2~0.8Mpa(29~114psi) Others 0.15~0.8Mpa(21~114psi) Proof pressure 1.2MPa(175psi) Temperature -20~70℃ Material of body Aluminum alloy Lubrication [Note 2] Not required Exhaust type of pilot valve Main valve aand pilot valve is centralized exhaust [Note 1]PT, NPT thread amd G thread are available.
[Note 2]Once lubricated air is used, continue with same medium to optimise valve life
span. Lubricants like ISO VG32 or equivalent are recommended.[Note 3]The maximum actuation frequency is in the no-load state.
[Note 4]Equivalent orifice S and Cv are all calculated from the flow rate data.。
-